{"id":4800,"date":"2022-06-30T14:24:07","date_gmt":"2022-06-30T12:24:07","guid":{"rendered":"https:\/\/il-metronic.com\/sensor-technology\/kuv-2-4-wr-reference-radiometer\/"},"modified":"2026-07-23T08:08:23","modified_gmt":"2026-07-23T06:08:23","slug":"kuv-2-4-wr-reference-radiometer","status":"publish","type":"page","link":"https:\/\/il-metronic.com\/en\/sensor-technology\/kuv-2-4-wr-reference-radiometer\/","title":{"rendered":"Reference Radiometer KUV 2.4 WR"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"4800\" class=\"elementor elementor-4800 elementor-4069\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-10929f0 elementor-section-height-min-height elementor-section-boxed elementor-section-height-default elementor-section-items-middle\" data-id=\"10929f0\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6ebfcfb\" data-id=\"6ebfcfb\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d8c4115 elementor-widget elementor-widget-heading\" data-id=\"d8c4115\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Reference Radiometer KUV 2.4 WR<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-48c32d5 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"48c32d5\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-191355c\" data-id=\"191355c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-17e5844 elementor-widget elementor-widget-image\" data-id=\"17e5844\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/il-metronic.com\/wp-content\/uploads\/2021\/02\/KUV-2.4.jpg\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"UV-Referenzmessger\u00e4te\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDQ5NCwidXJsIjoiaHR0cHM6XC9cL2lsLW1ldHJvbmljLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyMVwvMDJcL0tVVi0yLjQuanBnIn0%3D\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"534\" src=\"https:\/\/il-metronic.com\/wp-content\/uploads\/2021\/02\/KUV-2.4.jpg\" class=\"attachment-large size-large wp-image-4494\" alt=\"\" srcset=\"https:\/\/il-metronic.com\/wp-content\/uploads\/2021\/02\/KUV-2.4.jpg 943w, https:\/\/il-metronic.com\/wp-content\/uploads\/2021\/02\/KUV-2.4-300x200.jpg 300w, https:\/\/il-metronic.com\/wp-content\/uploads\/2021\/02\/KUV-2.4-768x512.jpg 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-0727f13\" data-id=\"0727f13\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3fd255a elementor-widget elementor-widget-text-editor\" data-id=\"3fd255a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"fusion-text fusion-text-1\"><p>The KUV 2.4 WR UV reference meter is designed as a reference meter in connection with UV sensors according to DVGW W294, \u00d6NORM M5873 and DIN 19294. It can also be used for checking UV systems in water treatment and to check the sensors installed in the system. Furthermore, digital plant sensors to be checked can additionally be connected and recalibrated by means of the reference radiometer.<\/p><\/div><div class=\"fusion-title title fusion-title-1 fusion-title-text fusion-title-size-four\"> <\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-313c8cb elementor-widget elementor-widget-heading\" data-id=\"313c8cb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Data sheets and information<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-86f4fa8 elementor-align-left elementor-tablet-align-left elementor-widget elementor-widget-button\" data-id=\"86f4fa8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/il-metronic.com\/wp-content\/uploads\/2021\/05\/Info_KUV2.4WR.pdf\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">data sheet KUV 2.4 WR reference radiometer<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a003b2f elementor-align-left elementor-tablet-align-left elementor-widget elementor-widget-button\" data-id=\"a003b2f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/il-metronic.com\/en\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Request now<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t<div class=\"elementor-element elementor-element-473d1dc e-flex e-con-boxed e-con e-parent\" data-id=\"473d1dc\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-35ce395 elementor-widget elementor-widget-heading\" data-id=\"35ce395\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">General Attributes<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-86f09bd e-con-full e-flex e-con e-child\" data-id=\"86f09bd\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t<div class=\"elementor-element elementor-element-a1e8410 e-con-full e-flex e-con e-child\" data-id=\"a1e8410\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef78ebf elementor-widget elementor-widget-text-editor\" data-id=\"ef78ebf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The UV measuring instrument KUV 2.4 WR is designed as reference radiometer in combination with UV sensors according to DVGW W294-3 and \/ or \u00d6NORM M5873. It is intended for monitoring of UV-facilities in water treatment and serves also for checking the duty sensors of the plant. Further it offers the opportunity to connect and recalibrate duty sensors of the model series SUV20\u2026Z4 or SUV20\u2026Z4Y.<br \/>A robust metal house protects the device from external impacts. The device is operated via three keys. Next to the power key there are two additional keys for display lighting and saving of measurement values available. The four measurement ranges are switching automatically. The measurement instrument is battery operated and has a two-line LCD display with background lighting. Additionally, a wall power supply for the casual supply voltages 110\/230 V AC is available. Further connection sockets are used for analog value output and bidirectional data transmission.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8064672 elementor-widget elementor-widget-heading\" data-id=\"8064672\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">TECHNICAL DATA<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1c66ec elementor-widget elementor-widget-text-editor\" data-id=\"c1c66ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table border=\"1\">\n  <tr>\n    <th>Parameter<\/th>\n    <th>Value<\/th>\n  <\/tr>\n  <tr>\n    <td>Mass<\/td>\n    <td>Ca. 790 g<\/td>\n  <\/tr>\n  <tr>\n    <td>Dimensions (W x H x D)<\/td>\n    <td>105\/80 x 230 x 35 mm<\/td>\n  <\/tr>\n  <tr>\n    <td>Housing<\/td>\n    <td>Aluminum case, color matt black<\/td>\n  <\/tr>\n  <tr>\n    <td>Battery operation time<\/td>\n    <td>Approximately 10 hours<\/td>\n  <\/tr>\n  <tr>\n    <td>Charging time<\/td>\n    <td>Approximately 4 hours with 0,5 A charging current<\/td>\n  <\/tr>\n  <tr>\n    <td>Display<\/td>\n    <td>LCD, 2 x 16 chars<\/td>\n  <\/tr>\n  <tr>\n    <td>Measuring ranges<\/td>\n    <td>2 \u2013 20 \u2013 200 \u2013 2000 W\/m\u00b2, automatic switch; minimal irradiation intensity 0,05 W\/m\u00b2<\/td>\n  <\/tr>\n  <tr>\n    <td>Analogue output<\/td>\n    <td>0,1 \u2013 4,1 V; jack plug 2,5 mm<\/td>\n  <\/tr>\n  <tr>\n    <td>Serial interface<\/td>\n    <td>RS232, jack plug 3,5 mm<\/td>\n  <\/tr>\n  <tr>\n    <td>Line adapter<\/td>\n    <td>110 &#8230; 240 V AC \/ 9 \u2013 12 V DC, 18 W, power plug EU, US, UK or AU<\/td>\n  <\/tr>\n  <tr>\n    <td>Degree of protection<\/td>\n    <td>IP65 case cover of connection box closed<\/td>\n  <\/tr>\n  <tr>\n    <td>Environmental conditions<\/td>\n    <td>Working and storage temperature: 0 \u2013 30\u00b0C; air humidity < 90% (no condensation)<\/td>\n  <\/tr>\n  <tr>\n    <td>Reference sensors<\/td>\n    <td>according to DVGW W294 or \u00d6NORM M5873-1, with cable and round plug connector M12: SUV 20.1 A1 Y1 R (DVGW W294, 30\u00b0); SUV 20.1 A2 Y1 R (\u00d6NORM M5873-1, 160\u00b0); SUV 20.2 A1 Y1 R (DVGW W294-3, 40\u00b0); SUV 20.2 A2 Y1 R (DVGW W294-3, 160\u00b0)<\/td>\n  <\/tr>\n  <tr>\n    <td>Duty sensors<\/td>\n    <td>according to DVGW W294 or \u00d6NORM M5873-1, digital interface (SUV20\u2026Z4(Y))<\/td>\n  <\/tr>\n<\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1624f1c elementor-widget elementor-widget-spacer\" data-id=\"1624f1c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Reference Radiometer KUV 2.4 WR The KUV 2.4 WR UV reference meter is designed as a reference meter in connection with UV sensors according to DVGW W294, \u00d6NORM M5873 and DIN 19294. It can also be used for checking UV systems in water treatment and to check the sensors installed in the system. Furthermore, digital [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":4780,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-4800","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/il-metronic.com\/en\/wp-json\/wp\/v2\/pages\/4800","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/il-metronic.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/il-metronic.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/il-metronic.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/il-metronic.com\/en\/wp-json\/wp\/v2\/comments?post=4800"}],"version-history":[{"count":15,"href":"https:\/\/il-metronic.com\/en\/wp-json\/wp\/v2\/pages\/4800\/revisions"}],"predecessor-version":[{"id":7119,"href":"https:\/\/il-metronic.com\/en\/wp-json\/wp\/v2\/pages\/4800\/revisions\/7119"}],"up":[{"embeddable":true,"href":"https:\/\/il-metronic.com\/en\/wp-json\/wp\/v2\/pages\/4780"}],"wp:attachment":[{"href":"https:\/\/il-metronic.com\/en\/wp-json\/wp\/v2\/media?parent=4800"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}